      As part of the TB screening workflow, the system shall create and manage Chest X-Ray test orders against a beneficiary's visit after completion of TB symptom screening. The system shall support automated and manual result entry, multiple test orders against the same visit, result-based referrals to Truenat, repeat testing for AI-invalid results, and automatic closure of pending orders at the end of the day.

      Source: Confluence AMRIT space — "Chest X-Ray Workflow Epic" (page 171737110) - Chest X-Ray Workflow Epic - AMRIT - Confluence

      Business Rules

      Rule ID Business Rule
      BR-CXR-01 A Visit ID shall be created after TB symptom screening is completed.
      BR-CXR-02 A new Chest X-Ray referral shall automatically create a unique Order ID.
      BR-CXR-03 Multiple X-Ray Order IDs may exist under one Visit ID.
      BR-CXR-04 Every Order ID is valid for the day on which it is created.
      BR-CXR-05 New orders shall have status Pending.
      BR-CXR-06 A valid X-Ray result shall change the order status to Completed.
      BR-CXR-07 AI Invalid Result shall close the current order and generate a new order for repeat testing.
      BR-CXR-08 A Not Conducted reason is mandatory before closing an order for a test that was not conducted.
      BR-CXR-09 Eligible open orders shall be automatically closed at EoD.
      BR-CXR-10 Closed orders shall not be deleted.
      BR-CXR-11 A new order can be manually created from a closed order when another test is required.
      BR-CXR-12 Each test attempt shall have a unique Test ID/Order ID as applicable.
      BR-CXR-13 Abnormal but not TB Presumptive and TB Presumptive results shall initiate Truenat referral.
      BR-CXR-14 Automated and manual result-entry mechanisms shall produce the same standardized result types and downstream workflow.

        1. shared image (70).jpeg
          shared image (70).jpeg
          239 kB
        2. shared image (69).jpeg
          shared image (69).jpeg
          304 kB
        3. shared image (68).jpeg
          shared image (68).jpeg
          318 kB
        4. shared image (67).jpeg
          shared image (67).jpeg
          269 kB
        5. Chest X-Ray Result-Based Workflow-4.png
          Chest X-Ray Result-Based Workflow-4.png
          1.60 MB

              Assignee:
              Brijesh Singh
              Reporter:
              Shivani Garg
              Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

                Created:
                Updated:
                Resolved: